app开发者平台在数字化时代的重要性与发展趋势解析
657
2022-09-20
solaris 消除告警信息
-> start /SP/faulttmgmt/shellstart: Invalid target /SP/faulttmgmt/shell
-> start /SP/faultmgmt/shellAre you sure you want to start /SP/faultmgmt/shell (y/n)? y
faultmgmtsp> fmadm faulty
Time UUID msgid Severity
2019-10-21/13:51:44 7d6be8a5-d27c-6e12-fd6b-b809cde44fe2 DISK-8000-0X Major
Fault class : fault.io.disk.predictive-failure
FRU : /SYS/MB/HDD0(Part Number: )(Serial Number: )
Description : A fault has been diagnosed by the Host Operating System.
Response : The service required LED on the chassis and on the affectedFRU may be illuminated.
Impact : No SP impact. Check the Host OS for more information.
Action : The administrator should review the fault on the Host OS. Please refer to the Details section of the Knowledge Articlefor additional information.
Time UUID msgid Severity
2019-06-25/17:30:25 4e46e6f2-66f8-c0d2-d9dc-f1558440291e DISK-8000-0X Major
Fault class : fault.io.disk.predictive-failure
FRU : /SYS/MB/HDD1(Part Number: )(Serial Number: )
Description : A fault has been diagnosed by the Host Operating System.
Response : The service required LED on the chassis and on the affectedFRU may be illuminated.
Impact : No SP impact. Check the Host OS for more information.
Action : The administrator should review the fault on the Host OS. Please refer to the Details section of the Knowledge Articlefor additional information.
faultmgmtsp> fmadm repair 7d6be8a5-d27c-6e12-fd6b-b809cde44fe2faultmgmtsp> fmadm repair 4e46e6f2-66f8-c0d2-d9dc-f1558440291e
版权声明:本文内容由网络用户投稿,版权归原作者所有,本站不拥有其著作权,亦不承担相应法律责任。如果您发现本站中有涉嫌抄袭或描述失实的内容,请联系我们jiasou666@gmail.com 处理,核实后本网站将在24小时内删除侵权内容。
发表评论
暂时没有评论,来抢沙发吧~